Synthes proximal femur plate
WebIn the proximal femur, the blade needs to be inserted in the middle of the femoral neck and at a predetermined angle to the shaft axis. In addition, the plate portion of the angled … Web333.200 Condylar Plate Guide Proximal femur: The 95º condylar plate guide is then placed along the lateral cortex and the guide wire B is in - serted, parallel in the axial view to the first guide wire and parallel with the upper edge of the condylar plate guide in the AP view. It is drilled into the greater trochanter just
Synthes proximal femur plate
Did you know?
WebWith anatomically contoured plates designed or validated using our proprietary SOMA technology, streamlined instrumentation, and trained representatives, our plating portfolio … Webfemur locking plates were 2.9 times more likely to incur a nonunion. However, other factors associated ... plates (Synthes), 17 (17.7%) first generation VA locking ... =0.25) (Table 2). The type of proximal plate screw fixation technique did affect union rate. Hybrid proximal screw constructs were used in 52 fractures (54.2%), all locking ...
WebThe proximal femur is resected through subperiosteal dissection, traveling distal to proximal, and excised ( Fig. 4D ). Compartmentalization The capsule is imbricated with #2 ethibond sutures ( Figs. 5A, B ). The trochanter is then affixed simultaneously to the imbricated capsule and remaining femoral shaft with #5 ethibond sutures ( Figs. 5C, D ).
Webthe plate on the proximal femur. Seat hooks using a 4.5 mm cortex screw aimed toward the calcar. Screw may be removed following insertion of 7.3 mm screw in the proximal fragment. Alternative: The impactor may be used to seat the hooks in the proximal fragment. Surgical Technique 8 Synthes LCP Proximal Femoral Hook Plate 4.5/5.0 Technique Guide WebThe system provides enhanced fixation in bone by using locking screws in the proximal and distal fragments. It also restores the mechanical axis of the lower limb through the use of multiple offsets, giving surgeons the ability to achieve reproducible results with uniquely designed instrumentation.
WebThe Synthes Locking Compression Plates—Narrow and Broad, are intended for fixation of various long bones, such as the humerus, femur and tibia. They are also for use in fixation of periprosthetic fractures, osteopenic bone, and nonunions or malunions. ... The Synthes LCP Proximal Tibia Plate is intended for treatment of non-unions, malunions,
WebTHP is indicated for both intracapsular fractures and intertrochanteric fractures of the proximal femur. ... 27244 Treatment of intertrochanteric, peritrochanteric, or subtrochanteric femoral fracture; with plate/screw type implant, with or without cerclage 27248 Open treatment of greater trochanteric fracture, includes internal fixation, when ... citypass tampa floridaWebThe Proximal Femur Plate and the Proximal Femur Hook Plate are the two main plates. The Greater Trochanter (GT) Ring Attachment Plate, VA Locking Attachment Plate and Distal … city pass vs sightseeing passWebThe DePuy Synthes VA-LCP PPFx Proximal Femur Plates and Proximal Femur Hook Plates 3.5/4.5/5.0 are indicated for the treatment of periprosthetic fractures and fractures in the presence of intramedullary implants in the proximal and middle 1/3 of the diaphyseal segment of the femur, in adult patients. Contraindications citypastoraat enschede anthonyWebLCP Pediatric Plate System LCP Periarticular Proximal Humerus Plate 3.5 LCP Posterior Medial Proximal Tibial Plate 3.5 LCP Proximal Femoral Hook Plate 4.5/5.0 LCP Proximal Femoral Plate 4.5/5.0 LCP Proximal Radius Plates 2.4 LCP Proximal Tibial Plate 3.5 LCP Proximal Tibial Plate 4.5/5.0 with Periarticular Aiming Arm Instruments LCP Superior ... citypass wyominghttp://synthes.vo.llnwd.net/o16/LLNWMB8/INT%20Mobile/Synthes%20International/eIFU-EMEA/532121/532121AReng.pdf dots clinic near meWebNext, a lateral distal femoral locking plate was placed; of note, a 7-cm incision was made at the level of the vastus ridge, to visualize and center the plate proximally. The plate was linked to the nail and fixed percutaneously in the shaft using the perfect circle technique. Finally, the proximal locking screws were placed in the rIMN. citypastoralWebproximal femur or frontal plane of the condyles Instrument 292.200.01 Kirschner Wire B 2.0 mm with trocar tip, length 150 mm, Stainless Steel For the proximal femur insert … city pass toronto canada